您可通過問題反饋或聯繫在線客服提交您的建議,我們將盡快完善:
Support
確定
??
不支持第三方 Cookie
您的瀏覽器不允許設置第三方 cookie。Please enable them in your browsers settings or click the button below.
請單擊此處在新選項卡中打開頁面內容。
If the opened page does not work initially, try reloading the page.
Please enable cookies in your browser for PARTcommunity to work
Catalog navigation
所有產品目錄
幾何搜索
草圖搜索
變量搜索
認證的產品目錄
按照分類
按照國家
按照標準
可提供的產品目錄語言:
Deutsch
English
English
QA認證資訊
目錄: Eaton's CAD
Created: 19.09.2017
產品目錄的特殊屬性:
Central management with the CADENAS quality tool PARTproject QA
Electronic test run was passed (CAD compatibility assured)
Only clear nomenclature -> ERP-compatibility assured
Eaton's CAD
187171
Eaton's CAD
Electrical circuit protection
23190
Moeller series xPole - AFDD+ Arc fault detection device
Powered by
CAD模型選擇
{eaton_cad/23128/23190/23370/23911.prj},{NB=187171},{PLID=187171},{NETTO_WEIGHT=0.27700},{EF001391=2},{EF000228=230},{EF000227=10},{EF002358=0.01},{EF002568=3},{EF012628=10},{EF006065=0},{EF000034=50},{EF002569=3},{EF002570=2},{EF002950=3},{EF000218=67},{EF007680=0},{EF007683=230},{CUSTOMS_TARIFF_NUMBER1=85363010},{PREVIEW=../../../_pool_/67/d2/97/23911_preview_250.png},{MANUTYPEDESC=AFDD-10/2/C/001-A},{DESCSHORT=Arc Fault Detection Device, 2p, C, 10 A, 10 mA, type A}
請根據技術需求選擇所需產品. 可選屬性在表格中高亮顯示. 選擇可以通過點擊表格或數值來重置.
可提供的產品: 50
HELP_VARIABLE
Company
Eaton's CAD
Description
Earth leakage circuit breaker with auxiliary device [EC002695]
Bill of material
187171
Preview
../../../_pool_/67/d2/97/23911_preview_250.png
../../../_pool_/67/d2/97/23911_preview_250.png
PLID
187171
187171
Manufacturer Type Description
AFDD-10/2/C/001-A
AFDD-10/2/C/001-A
Short Description
Arc Fault Detection Device, 2p, C, 10 A, 10 mA, type A
Arc Fault Detection Device, 2p, C, 10 A, 10 mA, type A
Long Description
High-quality arc fault detection device (AFDD) with residual current device/miniature circuit breaker combination, line voltage-independent, contact position indicator red - green, terminal rear plug protection, tri-stable slide catch - enables removal from existing busbar system, comprehensive range of accessories suitable for subsequent installation, wide range of rated fault currents, rated operational currents up to 40 A, tripping characteristics B, C, D, rated breaking capacity 10 kA, suitable for outdoor use (on-site power and outdoor distribution board) up to -25 °C
High-quality arc fault detection device (AFDD) with residual current device/miniature circuit breaker combination, line voltage-independent, contact position indicator red - green, terminal rear plug protection, tri-stable slide catch - enables removal from existing busbar system, comprehensive range of accessories suitable for subsequent installation, wide range of rated fault currents, rated operational currents up to 40 A, tripping characteristics B, C, D, rated breaking capacity 10 kA, suitable for outdoor use (on-site power and outdoor distribution board) up to -25 °C
International product number
4015081822201
4015081822201
Netto weight
0.27700
kg
ECLASS_13_0
Earth leakage circuit breaker with auxiliary device [ADI479012]
ETIM_9_0
Earth leakage circuit breaker with auxiliary device [EC002695]
Number of poles
2
Rated voltage
230
V
Rated current
10
10
A
Rated fault current
0.01
0.01
A
Leakage current type
A
A
Current limiting class
3
Rated short-circuit breaking capacity according to EN 61009
10
10
kA
Rated short-circuit breaking capacity according to IEC 60947-2
0
kA
Frequency
50
Hz
Release characteristic
C
C
Concurrently switching neutral conductor
false
Over voltage category
3
Pollution degree
2
Width in number of modular spacings
3
Built-in depth
67
mm
Additional equipment attached at delivery
Fire protection switch
Rated switch current auxiliary device
0
A
Rated voltage auxiliary device
230
V
Control voltage type auxiliary equipment
AC
Degree of protection (IP)
IP20
Data sheet